All projects

Controls & integration

Process interlocks for a juice homogenizer

A relay circuit tied homogenizer operation to three conditions on a juice-processing line.

Founder’s electrical controls experience

Engineering challenge

The machine needed to stop if the feed ran dry, temperature left its operating range or the receiving tank filled.

Technical solution

A hardwired permissive combined inlet and tank level switches with a temperature signal from the heat exchanger.

Implementation

Two vibrating-fork sensors detected product at the inlet and high level downstream. Relays evaluated the signals and controlled the run permission.

Outcome

With the interlocks active, a failed process condition stopped the homogenizer.

Start a conversation

Have an engineering challenge?

Let’s find a better way forward.

Discuss Your Project