All projects

Controls & integration

Removing static and dust from bottle caps

A cap-cleaning system combined ionized air with vacuum extraction for a bottling application in Qatar.

Founder’s design and commissioning work with AG Automation Solutions

Engineering challenge

Static charge could hold dust on caps as they passed through the cleaning station. The system was designed for a line handling 27,000 caps per hour.

Technical solution

Ionizing bars neutralized the charge. A filtered vacuum removed dislodged particles, while the controller monitored the process.

Implementation

Ameed selected components and developed the electrical design and PLC software. On site, he completed the electrical installation, checked airflow and tuned the system. Filter differential pressure provided a maintenance signal.

Outcome

The cap-rinsing and blower system was installed and tuned on site.

Start a conversation

Have an engineering challenge?

Let’s find a better way forward.

Discuss Your Project